Funiculus Potentiae H05Z1-U/R/K ad Sensores et Actuatores Connectendos
CONSTRUCTIO FUNICULORUM
Conductor: Conductor cupreus secundum BS EN 60228 classem 1/2/5.
Insulatio: Mixtura thermoplastica generis TI 7 secundum EN 50363-7.
Optio Insulationis: Resistentia UV, resistentia hydrocarbonum, resistentia oleo, proprietates anti-rodentes et anti-termites ut optiones offerri possunt.
EFFECTUS IGNIS
Retardatio Flammae (Experimentum unius fili verticalis vel funis): IEC 60332-1-2; EN 60332-1-2
Propagatio Ignis Reducta (Examen Filorum et Funium Verticaliter Impositorum): IEC 60332-3-24; EN 60332-3-24
Halogen Free:IEC 60754-1; EN 50267-2-1
Nulla Emissio Gasorum Corrosivorum: IEC 60754-2; EN 50267-2-2
Minimum Emission:IEC 61034-2; EN 61034-2
TENSIONIS CLASSIFICATIO
300/500V
CONSTRUCTIO FUNICULORUM
Conductor: Conductor cupreus secundum BS EN 60228 classem 1/2/5.
Insulatio: Mixtura thermoplastica generis TI 7 secundum EN 50363-7.
Optio Insulationis: Resistentia UV, resistentia hydrocarbonum, resistentia oleo, proprietates anti-rodentes et anti-termites ut optiones offerri possunt.
PROPRIETATES PHYSICAE ET THERMICAE
Temperatura maxima in operatione: 70°C
Temperatura maxima circuitus brevis (5 secunda): 160°C
Radius flexionis minimus: 4 x Diametrus Totalis
CODEX COLORUM
Niger, caeruleus, fuscus, griseus, aurantiacus, roseus, ruber, turchesis, violaceus, albus, viridis et flavus. Bicolores cuiuslibet combinationis monocolorum supradictorum permittuntur.
PROPRIETATES
Protectio Ambitus: Ob usum materiarum insulationis sine halogenis et fumo parvo emittentium, funiculus electricus gases corrosivos non producit cum ardet, quod et apparatibus electricis et ambitu amicum est.
Salus: Eius proprietates sine halogenis, fumo parvo emittente, salutem augere possunt cum in locis publicis (velut aedificiis publicis, etc.) ubi fumus et gases toxici minas vitae et damnum instrumentorum inferre possunt, adhibentur.
Durabilitas: Bona resistentia calori et resistentia chemica habet et apta est variis ambitus internis, inter quos sunt ambientes siccos et humidos.
Ambitus applicationis: Idoneum est ad filationem instrumentorum illuminationis et filationem instrumentorum pretiosorum quae ab igne protegenda sunt.
APPLICATIO
Filatio interna: Funes electrici late adhibentur ad filationem internam systematum illuminationis interioris, instrumentorum domesticorum, instrumentorum officii, etc.
Loca publica: Adhibetur in filis internis apparatuum electricorum in locis publicis, ut aedificiis publicis, scholis, valetudinariis, etc., praesertim in locis ubi salus personarum et protectio apparatuum consideranda est.
Usus industriales: In apparatu industriali et systematibus moderandis, ad sensoria, actuatores, aliaque elementa electrica connectenda adhibetur, praesertim in ambitu cum temperaturis altis et requisitis specialibus salutis.
PARAMETRI CONSTRUCTIONIS
Conductor | FTX100 05Z1-U/R/K | ||||
Numerus Nucleorum × Area Sectionis Transversalis | Classis Directoris | Crassitudo Nominalis Insulationis | Diameter Totalis Minimus | Diameter Maximus Totalis | Pondus approximatum |
Numerus × mm² | mm | mm | mm | chiliogrammata/chilometrum | |
1×0.50 | 1 | 0.6 | 1.9 | 2.3 | 9.4 |
1×0.75 | 1 | 0.6 | 2.1 | 2.5 | 12.2 |
1×1.0 | 1 | 0.6 | 2.2 | 2.7 | 15.4 |
1×0.50 | 2 | 0.6 | 2 | 2.4 | 10.1 |
1×0.75 | 2 | 0.6 | 2.2 | 2.6 | 13 |
1×1.0 | 2 | 0.6 | 2.3 | 2.8 | 16.8 |
1×0.50 | 5 | 0.6 | 2.1 | 2.5 | 9.9 |
1×0.75 | 5 | 0.6 | 2.2 | 2.7 | 13.3 |
1×1.0 | 5 | 0.6 | 2.4 | 2.8 | 16.2
|
PROPRIETATES ELECTRICAE
Temperatura operationis conductoris: 70°C
Temperatura ambientis: 30°C
Capacitates Currentis Portandae (Amp)
Area Sectionis Transversalis Conductoris | AC monophasicum | Triphasicum AC |
mm² | A | A |
0.5 | 3 | 3 |
0.75 | 6 | 6 |
1 | 10 | 10 |
Nota: Hae valores ad plurimos casus pertinent. Plura informationes in casibus insolitis quaerendae sunt, e.g.: | ||
(i) Cum temperaturae ambientis altae aguntur, id est, supra 30℃ | ||
(ii) Ubi longiores partes adhibentur | ||
(iii) Ubi ventilatio restricta est | ||
(iv) Ubi funiculi ad alios usus adhibentur, e.g., nexus internus apparatus. |
Casus Tensionis (Per Ampere Per Metrum)
area sectionis transversalis ductoris | Duo funes DC | Duo funes, monophasici AC | Tres vel quattuor funes, triphasici AC | |||||
Methodi A et B (in ductu vel canali inclusae) | Methodi C, F et G (directe tondeantur, in alveolis vel in aere libero) | Methodi A et B (in ductu vel canali inclusae) | Methodi C, F et G (directe tondeantur, in alveolis vel in aere libero) | |||||
Funes tangentes | Funibus inter se distantibus* | Funes tangentes, Trifolium | Funes tangentes, plani | Funes inter se distantes*, plani | ||||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
mm² | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m | mV/A/m |
0.5 | 93 | 93 | 93 | 93 | 80 | 80 | 80 | 80 |
0.75 | 62 | 62 | 62 | 62 | 54 | 54 | 54 | 54 |
1 | 46 | 46 | 46 | 46 | 40 | 40 | 40 | 40 |
Nota: *Spatia maior quam unum diametrum funis magnum casum tensionis efficient.